00 39 0185 35271

+39 335 5756339

CMF#NJ

SPRING RETURN CYLINDERS WITH HOLLOW PISTON FOR BARRIERS TYPE NEW JERSEY
AND GUARD-RAILS

force: 10-20t
stroke: 8-50mm
max working pressure: 700bar

Features

INTRODUCTION AND OPERATIONAL AREAS

The Europress system model CMF22N8S##NJ is used to verify and test the studs in New Jersey barriers and guard rails. The barriers both New Jersey, steel or concrete, and the guard rails are fixed to the road thanks to studs which generally have M16, M20 or M24 dimensions. Both during the installation and the exercise of the studs it’s necessary to verify them through traction tests in order to prove their adherence to concrete and the integrity of the material. To this purpose the Europress system allows to fulfill simple and efficient tensile strength tests. The system is composed of a traction load cell CMF22N8G constituted by a simple effect spring return hollow ram cylinder, with a nominal capacity of a maximum of 212 kN at 700 bars, 8 mm of stroke, firmly connected to a gauge and provided with a quick female coupler combined with a pump which generates hydraulic pressure. This traction cell constitutes an instrument to measure the force applied on the stud while testing. If calibrated as a measurement instrument it can be used also to redact calibration certificated tests. Depending on the different applications required the set can be equipped with ancillaries which are useful to the traction of studs of M16, M20, M24 diameter. Moreover it can be used a longer M20 diameter version for the traction of studs fixed on steel New Jersey barriers. The cylinder is activated by a PNP130 (or PN131) hand pump and a flexible hose SN20M with a male coupler on top.The pump is connected thanks to the male coupler fixed on one side of the hose which is connected to the female coupler fixed on the cylinder. The hollow ram cylinder, thanks to its through hole, allows the passage of the tie-rod of appropriate dimension in order to  screw it on the stud itself. Extending the piston of the cylinder, a tensile force, proportional to the pressure generated by the pump, is exerted on the stud. The gauge allows at last to verify and control the force exerted on the stud.

SET CHOICE

The load cell CMF22N8G is suitable for all the sets and it’s adjustable to certify the extent of the applied force. The set CMF22N8S1624NJC, which is available in our stock, includes all the necessary articles to compose the illustrated variants, in particular:
– 1 pcs. Load cell CMF22N8G ;
– 1 pcs. Base 320220820 ;
– 1 pcs. Extended base 320200821 for barriers type New Jersey in steel ;
– 3 pcs. Screws 3001108025 ;
– 1 pcs. Knub 320220700 ;
– 1 pcs. Puller M16 320220716 ;
– 1 pcs. Puller M20 320220720 ;
– 1 pcs. Puller M20 long 320220721 for extended base ;
– 1 pcs. Puller M24 320220724.

Selection chart

MODEL

A

B

C  (puller code)

D  (base code)

kg

CMF22N8S16NJ

M16

27

320200716

320200820

8,3

CMF22N8S20NJ

M20

30

320200720

320200820

8,3

CMF22N8S20NJL

M20

27

 320200721

320200821

9,6

CMF22N8S24NJ

M24

30

 320200724

320200820

8,3

CMF20N8S1624NJ

M16/M20/M24

27/30

INTRODUCTION AND OPERATIONAL AREAS

The Europress system model CMF22N50S##NJ is used to verify and test the studs in New Jersey barriers and guard rails. The barriers both New Jersey, steel or concrete, and the guard rails are fixed to the road thanks to studs which generally have M16, M20, M24, M27 and M30 dimensions. Both during the installation and the exercise of the studs it’s necessary to verify them through traction tests in order to prove their adherence to concrete and the integrity of the material. To this purpose the Europress system allows to fulfill simple and efficient tensile strength tests. The system is composed of a traction load cell CMF22N50 constituted by a simple effect spring return hollow ram cylinder, with a nominal capacity of a maximum of 230 kN at 700 bars, 50 mm of stroke, firmly connected to a gauge and provided with a quick female coupler combined with a pump which generates hydraulic pressure. This traction cell constitutes an instrument to measure the force applied on the stud while testing. If calibrated as a measurement instrument it can be used also to redact calibration certificated tests. Depending on the different applications required the set can be equipped with ancillaries which are useful to the traction of studs of M16, M20, M24, M27 and M30 diameter. Moreover it can be used a longer M20 diameter version for the traction of studs fixed on steel New Jersey barriers.The cylinder is activated by a PNP130G (or PN131G) hand pump and a flexible hose SN20M with a male coupler on top. The pump is connected thanks to the male coupler fixed on one side of the hose which is connected to the female coupler fixed on the cylinder. The hollow ram cylinder, thanks to its through hole, allows the passage of the tie-rod of appropriate dimension in order to  screw it on the stud itself. Extending the piston of the cylinder, a tensile force, proportional to the pressure generated by the pump, is exerted on the stud. The gauge allows at last to verify and control the force exerted on the stud.

HOW TO CHOOSE A SET

The CMF20N50 cylinder is suitable for every set. All the sets can be supplied as single sets or it’s also available a set which includes them all, it’s the CMF20N50S1630NJC, more specifically:

– 1 pz. Cylinder CMF20N50;
– 1 pz. 320200820 hollow spacer for open M16 ed M20 New Jersey barriers *;
– 1 pz. 320200821 extended spacer for enclosed M20 New Jersey barriers**;
– 1 pz. 320200824 extended spacer for Guard-Rails M20**, M24, M27 ed M30***;
– 2 pz. Screw 3001108025;
– 1 pz. Screw 3001108180;
– 1 pz. Rod M16 320200716*;
– 1 pz. Rod M20 320200720*;
– 1 pz. M20 320200721 extension for estended base**;
– 1 pz. Adaptor M20 320200720E**;
– 1 pz. Adaptor M24 320200724***;
– 1 pz. Adaptor M27 320200727***;
– 1 pz. Adaptor M30 3202007230***;

The components of the set are illustrated in the drawing underneath.

*  Allows the total extraction of the M16 with the nut, tests with M20 on 10 mm with nut or total extraction without the nut. Maximum applicable force 110 kN.
**Maximum applicable force with M20 110kN rod     *** Maximum applicable force with M24, M27 ed M30 80kN rod

Selection chart

MODEL

A

B

C  (puller code)

D  (base code)

kg

CMF20N50S16NJ*

M16

20

320200716

320200820

9,5

CMF20N50S20NJ*

M20

20

320200720

320200820

9,5

CMF20N50S20NJL**

M20

20

320200720 + 320200721

320200821

10,8

CMF20N50S20NJ**

M20

25

320200720 + 320200720E

320200824

11

CMF20N50S24NJ***

M24

25

320200720 + 320200724

320200824

11

CMF20N50S27NJ***

M27

25

320200720 + 320200727

320200824

11

CMF20N50S30NJ***

M30

25

320200720 + 320200730

320200824

11

CMF20N50S1630NJC

M16 / M20 / M24 / M27 / M30

20 / 25

Check associated products

applications

Civil Engineering & Constructions

Maintenances

READY DELIVERY

Thanks to our speedy deliveries you don’t have the urge to place a huge stock order to assure your customers a good service